Note
The specified parameters are located on the second parameter level. The parameters P 5.0, P 5.01, and P 5.4 require a special code and can therefore only be set with an authorisation from ABUS.
Access to the third parameter level is reserved for ABUS!
Parameter |
Setting range / unit |
Name |
See |
P 0.0 |
0 t – 100 t |
Maximum load capacity |
|
P 0.1 |
0 t – 80 t |
Maximum load capacity of hoist 1 |
|
P 1.1 |
0 – 17 |
Motor type |
|
P 1.2 |
0 – 97, 999 |
Winding resistance |
|
P 1.3 |
|
Current correction factor |
|
P 2.1 |
|
Setting slow lifting speed |
|
P 2.2 |
|
Setting fast lifting speed |
|
P 2.3 |
|
Setting with test load (teach-in) |
|
P 2.4 |
|
Device diagnosis |
|
P 3.0 |
In t |
Load display |
|
P 3.1 |
In kW |
Rotating field power |
|
P 3.2 |
In t |
Load display with deactivated overload protection |
|
P 3.3 |
In A |
Motor current |
|
P 3.4 |
In V |
Mains voltage |
|
P 3.41 |
|
Mains voltage analysis |
|
P 4.0 |
0 % − 110 % |
Load-controlled switching point |
|
P 4.1 |
0 % − 110 % |
Switching point of overload protection of hoist 1 |
|
P 4.2 |
0 % − 110 % |
Second load-controlled switching point |
|
P 4.3 |
|
Without function |
|
P 4.4 |
0, 1, 2 |
Operation on a twin hoist |
|
P 5.0 |
300 ms – 460 ms |
Measuring time extension |
|
P 5.01 |
20 − 255 |
Sensitivity of “rapid load increase” |
|
P 5.1 |
In h |
Theoretical service life |
|
P 5.2 |
In h |
Reading the load population recorder |
|
P 5.3 |
|
Test at the inspection before initial commissioning |
|
P 5.4 |
12 – 30 |
Inching counter |
|
P 5.5 |
|
Delete all values |
|
P 6.1 |
In h |
Input of starting value |
|
P 6.2 |
In h |
Actual hours of use S |
|
P 6.3 |
In h |
Operating hours Ti |
|
P 6.4 |
In h |
Input of theoretical service life |
|
P 6.5 |
|
Deleting load population recorder |
|
P 7.0 |
|
Accessing parameter level 3 |
|
P 9.9 |
|
Exiting the parameter level |