Overview of parameters

 

Note

The specified parameters are located on the second parameter level. The parameters P 5.0, P 5.01, and P 5.4 require a special code and can therefore only be set with an authorisation from ABUS.

Access to the third parameter level is reserved for ABUS!

 

Parameter

Setting range / unit

Name

See

P 0.0

0 t – 100 t

Maximum load capacity

P 0.0 Maximum load capacity

P 0.1

0 t – 80 t

Maximum load capacity of hoist 1

P 0.1 Maximum load capacity of hoist 1

P 1.1

0 – 17

Motor type

P 1.1 Motor type

P 1.2

0 – 97, 999

Winding resistance

P 1.2 Winding resistance

P 1.3

 

Current correction factor

P 1.3 Current correction factor

P 2.1

 

Setting slow lifting speed

P 2.1 Setting

P 2.2

 

Setting fast lifting speed

P 2.2 Setting

P 2.3

 

Setting with test load (teach-in)

P 2.3 Setting with test load (teach-in)

P 2.4

 

Device diagnosis

P 2.4 Device diagnosis

P 3.0

In t

Load display

P 3.0 Load display

P 3.1

In kW

Rotating field power

P 3.1 Rotating field power

P 3.2

In t

Load display with deactivated overload protection

P 3.2 Load display

P 3.3

In A

Motor current

P 3.3 Motor current

P 3.4

In V

Mains voltage

P 3.4 Mains voltage

P 3.41

 

Mains voltage analysis

P 3.41 Mains voltage analysis

P 4.0

0 % − 110 %

Load-controlled switching point

P 4.0 Load-controlled switching point

P 4.1

0 % − 110 %

Switching point of overload protection of hoist 1

P 4.1 Switching point of overload protection of hoist 1

P 4.2

0 % − 110 %

Second load-controlled switching point

P 4.2 Second load-controlled switching point

P 4.3

 

Without function

 

P 4.4

0, 1, 2

Operation on a twin hoist

P 4.4 Operation on twin hoists

P 5.0

300 ms – 460 ms

Measuring time extension

P 5.0 Measuring time extension

P 5.01

20 − 255

Sensitivity of “rapid load increase”

P 5.01 Sensitivity of “rapid load increase”

P 5.1

In h

Theoretical service life

P 5.1 Theoretical service life

P 5.2

In h

Reading the load population recorder

P 5.2 Load population recorder

P 5.3

 

Test at the inspection before initial commissioning

P 5.3 Test at the inspection before initial commissioning

P 5.4

12 – 30

Inching counter

P 5.4 Inching counter

P 5.5

 

Delete all values

P 5.5 Deleting values

P 6.1

In h

Input of starting value

P 6.1 Starting value

P 6.2

In h

Actual hours of use S

P 6.2 Actual hours of use

P 6.3

In h

Operating hours Ti

P 6.3 Operating hours Ti

P 6.4

In h

Input of theoretical service life

P 6.4 Input of theoretical service life

P 6.5

 

Deleting load population recorder

P 6.5 Deleting values (including load population recorder)

P 7.0

 

Accessing parameter level 3

P 7.0 Password input for parameter level 3

P 9.9

 

Exiting the parameter level

P 9.9 Exiting the parameter level