Value |
Meaning |
0 |
Fast lifting speed without additional time delay |
1 |
0.5 s time delay |
2 |
1 s time delay |
Select parameter P 4.4 with
the arrow buttons.
● The parameter is opened.
Hold Enter pressed until “Code”
appears in the display.
Hold Enter pressed.
Enter code 1443.
Depending on area of use, select
the following setting with the arrow buttons:
Mode of operation |
Device 1 |
Device 2 |
1 hoist |
0 |
- - - |
2 hoists working in parallel |
1 |
1 |
Operation on a twin hoist |
1 |
2 |
Press Enter briefly.
● The entered value is saved.