P 3.2 Load display with deactivated overload protection

As in parameter P 3.0, but the overload protection is deactivated! The crane is nevertheless functional in this parameter and can lift/lower, since the raised load can only be measured with the motor running.

 

Warnung stürzende Last

Danger due to deactivated overload protection!

The overload protection is deactivated in this parameter.

This can lead to an overload of the crane. This in turn means the raised load could fall and kill or injure people!

Do not overload the crane and always operate it with caution.

 

 

*   Select parameter P 3.2 with the arrow buttons.

*   Press Enter briefly.

●   The parameter is opened and “ABUS“ and “00.00” are shown alternatingly in the display.

*   Lift the load.

●   The current value of the raised load and “ABUS” are shown alternatingly in the display.

 

Next, the parameter level must be called up again in order to exit the parameter:

 

*   Hold Enter pressed until “Code” or “P-nr” appears in the display.

*   Open the parameter level.

*   Exit the parameter level via P 9.9.