This parameter enables you to extend the measuring time during start-up of the motor. This can be necessary, for example, due to a mains voltage that is too low, since the start-up current flows for longer than 300 ms. In this case, an overload would be interpreted after 300 ms due to the high start-up current, which is however not an overload but triggered by the lack of motor torque resulting from the insufficient mains voltage.
Note
Default setting: 300 ms
The measuring time can be extended to maximally 460 ms.
The parameter can only be accessed with a special code! Whenever adjustment of the measuring time extension is necessary, contact your ABUS Service representative. See “4”, page .
Select parameter P 5.0 with the arrow buttons.
Press Enter briefly.
● The parameter is opened.
● The current value is displayed.
Hold Enter pressed until “Code” appears in the display.
Hold Enter pressed.
Enter code.
Press Enter briefly.
Input the value with the arrow buttons.
Press Enter briefly.
● The value is saved.