P 4.0 Load-controlled switching point

In this parameter you set the load-controlled switching point in the range from 0% to 110% of the maximum load capacity. The value can be set in 2% steps.

The load-controlled switching point is activated through the switching of input EA on the LIS-SE. This enables, for example, implementation of partial load ranges (reduced maximum load capacity of the main girder, e.g. on the edge), which are switched by a cross-type limit switch.

 

*   Select parameter P 4.0 with the arrow buttons.

*   Press Enter briefly.

*   Set the value between 0% and 110% of the maximum load capacity.

*   Press Enter briefly.

●   The value is saved.