P 3.1 Rotating field power

In this parameter you can read the currently evaluated rotating field power [in kW]. The measurement can only be made with the motor running in “Lift” mode. After switching off the motor, the last displayed value is shown until a new measurement is made. The crane is therefore functional in this parameter and can lift/lower.

The overload protection is deactivated in this parameter.

 

Warnung stürzende Last

Danger due to deactivated overload protection!

The overload protection is deactivated in this parameter.

This can lead to an overload of the crane. This in turn means the raised load could fall and kill or injure people!

Do not overload the crane and always operate it with caution.

 

 

*   Select parameter P 3.1 with the arrow buttons.

*   Press Enter briefly.

●   The parameter is opened and the current value is displayed.

 

Next, the parameter level must be called up again in order to exit the parameter:

 

*   Hold Enter pressed until “Code” or “P-nr” appears in the display.

*   Open the parameter level.

*   Exit the parameter level via P 9.9.