With this parameter you enter the ohmic resistance of the winding for the fast and slow lifting speeds. The winding resistance [in ohms] is measured directly on the motor or on the central control at contactor K23.
Opening/reading parameters
Select parameter P 1.2 with
the arrow buttons.
Press Enter briefly.
● The parameter is opened.
● The value of the winding resistance at slow lifting speed is displayed.
Press Enter briefly.
● The value of the winding resistance at fast lifting speed is displayed.
Press Enter briefly.
● “└ - -” is shown in the display.
Press Enter briefly.
● Parameter P 1.2 is displayed.
Select parameter P 1.2 with
the arrow buttons.
Press Enter briefly.
● The parameter is opened.
● The current value of the winding resistance at slow lifting speed is displayed.
Press Enter briefly.
● The current value of the winding resistance at fast lifting speed is displayed.
Press Enter briefly.
● “└ - -” is shown in the display.
Hold Enter pressed until “Code”
appears in the display.
Hold Enter pressed.
Enter code 1443.
Press Enter briefly.
Enter the first value of the
resistance [in ohms] for the slow lifting speed using the arrow buttons.
Press Enter briefly.
Enter the second value of the
resistance [in ohms] for the fast lifting speed using the arrow buttons.
Press Enter briefly.
● The values are saved.