P 3.0 Load display

This parameter shows the value [in t] of the last lifted load. This is only possible with the motor running. After switching off the motor or when lowering, the last displayed value is shown again. When lifting is resumed, the load display is updated and shows the current value of the load. The crane is therefore functional in this parameter and can lift/lower.

The overload protection is active in this parameter.

 

*   Select parameter P 3.0 with the arrow buttons.

*   Press Enter briefly.

●   The parameter is opened and “ABUS“ and “00.00” are shown alternatingly in the display.

*   Lift the load.

●   The current value of the raised load and “ABUS” are shown alternatingly in the display.

 

Next, the parameter level must be called up again in order to exit the parameter:

 

*   Hold Enter pressed until “Code” or “P-nr” appears in the display.

*   Open the parameter level.

*   Exit the parameter level via P 9.9.