P 2.2 Setting fast lifting speed

Under this parameter you can read the saved values for the fast lifting speed or enter new values.

 

Display

Number

Meaning

Last

-1-

Test load with empty load hook at fast lifting speed.

Po-r

-1-

Rotating field power with empty load hook at fast lifting speed.

Last

-2-

Test load at fast lifting speed.

Po-r

-2-

Rotating field power with test load at fast lifting speed.

 

 

Reading out values:

 

 

 

 

*   Select parameter P 2.2 with the arrow buttons.

*   Press Enter briefly.

●   “Last” and then “-1-” is shown on the display.

*   Press Enter briefly.

●   The saved value for “Last -1-” is displayed.

 

 

 

 

 

 

*   Press Enter briefly.

●   “Po-r” and then “-1-” is shown on the display.

*   Press Enter briefly.

●   The saved value for “Po-r -1-” is displayed.

 

 

 

 

 

 

*   Press Enter briefly.

●   “Last” and then “-2-” is shown on the display.

*   Press Enter briefly.

●   The saved value for “Last -2-” is displayed.

 

 

 

 

 

 

*   Press Enter briefly.

●   “Po-r” and then “-2-” is shown on the display.

*   Press Enter briefly.

●   The saved value for “Po-r -2-” is displayed.

 

 

Entering values:

 

 

 

 

 

*   Select parameter P 2.2 with the arrow buttons.

*   Press Enter repeatedly until “└ - -” is displayed.

 

 

 

 

 

 

 

*   Hold Enter pressed until “Code” appears in the display.

*   Hold Enter pressed.

*   Enter code 1443.

 

 

 

 

 

 

*   Press Enter briefly.

●   “Last” and then “-1-” is shown on the display.

*   Press Enter briefly.

*   Input the desired value for “Last -1-” with the arrow buttons.

 

 

 

 

 

 

*   Press Enter briefly.

●   “Po-r” and then “-1-” is shown on the display.

*   Press Enter briefly.

*   Input the desired value for “Po-r -1-” with the arrow buttons.

 

 

 

 

 

 

*   Press Enter briefly.

●   “Last” and then “-2-” is shown on the display.

*   Press Enter briefly.

*   Input the desired value for “Last -2-” with the arrow buttons.

 

 

 

 

 

 

*   Press Enter briefly.

●   “Po-r” and then “-2-” is shown on the display.

*   Press Enter briefly.

*   Input the desired value for “Po-r -2-” with the arrow buttons.

*   Press Enter briefly.

●   P 2.2 is displayed and the values are saved.