Measure the rope wedge protrusion (lower
edge of rope wedge to lower edge of rope socket).
Measure the rope clamp spacing (upper edge of dead end rope grip to
lower edge of rope wedge).
The measured values must not be higher than the values in the
table.
Size |
Maximum rope wedge protrusion |
Minimum rope wedge protrusion |
GM 800 |
19 mm |
18 mm |
GM 1000 |
4 mm |
3 mm |
GM 2000 |
2 mm |
0 mm |
GM 3000 |
18 mm |
16 mm |
If the rope wedge protrudes too far out of the rope socket, or if the
dead end rope grip is too close to the rope wedge: replace rope socket and rope
wedge. See Replacing the
wire rope.
The minimum rope clamp spacing specified is always exactly equal to the wire rope diameter of the wire rope hoist.