Technical data

Technical data for the crane, electrical data for the drives, structural design, etc.: see the crane's test log book.

 

Electrical connection

 

Jib crane VW 35, 50, 60 with slewing gear SWG 50, 65, 80

Operating voltage

360 – 400 V

208 – 230 V

220 – 240 V

Mains frequency

60 Hz

60 Hz

50 Hz

Connection

Star

Delta

Delta

Duty cycle

30 %

30 %

30 %

Switching rate

240 c/h

240 c/h

240 c/h

Rated power

0.12 / 0.5 kW

0.12 / 0.5 kW

0.11 / 0.45 kW

Start-up current

2.6 / 13.8 A

4.5 / 23.2 A

3.6 / 18.1 A

Rated current

1.4 / 2.5 A

2.5 / 4.3 A

1.9 / 3.5 A

cos phi

0.55 / 0.55

0.55 / 0.55

0.6 / 0.6

 

 

Jib crane VW 35, 50, 60 with slewing gear SWG 50, 65, 80

Operating voltage

380 – 415 V

440 – 480 V

460 – 500 V

550 – 600 V

Mains frequency

50 / 60 Hz

50 / 60 Hz

Connection

Star

Star

Duty cycle

30 %

30 %

Switching rate

240 c/h

240 c/h

Rated power

0.11 / 0.45 kW

0.12 / 0.5 kW

0.11 / 0.45 kW

0.12 / 0.5 kW

Start-up current

2.0 / 10.4 A

1.8 / 10.4 A

1.7 / 8.8 A

1.5 / 8.6 A

Rated current

1.1 / 2.0 A

1.0 / 1.9 A

0.9 / 1.7 A

0.8 / 1.6 A

cos phi

0.6 / 0.6

0.55 / 0.55

0.6 / 0.6

0.55 / 0.55

 

 

Jib crane VW 70 with
slewing gear SWG 100

Operating voltage

360 – 400 V

208 – 230 V

220 – 240 V

Mains frequency

60 Hz

60 Hz

50 Hz

Connection

Star

Delta

Delta

Duty cycle

30 %

30 %

30 %

Switching rate

240 c/h

240 c/h

240 c/h

Rated power

0.3 / 1.2 kW

0.3 / 1.2 kW

0.25 / 1.0 kW

Start-up current

4.1 / 19.8 A

6.6 / 29.5 A

5.6 / 25.2 A

Rated current

2.2 / 3.6 A

3.5 / 5.4 A

2.9 / 4.8 A

cos phi

0.49 / 0.65

0.49 / 0.65

0.53 / 0.7

 

 

Jib crane VW 70 with
slewing gear SWG 100

Operating voltage

380 – 415 V

440 – 480 V

460 – 500 V

550 – 600 V

Mains frequency

50 / 60 Hz

50 / 60 Hz

Connection

Star

Star

Duty cycle

30 %

30 %

Switching rate

240 c/h

240 c/h

Rated power

0.25 / 1.0 kW

0.3 / 1.2 kW

0.25 / 1.0 kW

0.3 / 1.2 kW

Start-up current

3.2 / 14.6 A

3.2 / 14.3 A

2.7 / 12.0 A

2.5 / 11.6 A

Rated current

1.7 / 2.8 A

1.7 / 2.6 A

1.4 / 2.3 A

1.3 / 2.1 A

cos phi

0.53 / 0.7

0.49 / 0.65

0.53 / 0.7

0.49 / 0.65

 

 

Noise emissions:

─     Noise emissions by the hoist: see chain hoist or wire rope hoist product manual.

─     Noise emissions by the trolley drive: see trolley product manual.

─     Noise emissions by the slewing drive: sound pressure level LP, m dB(A) at a 1 m distance: 70 dB(A)

Noise emissions on the basis of DIN 45635, part 61, according to the substitution method using a sound power source.