LIS-SV
LIS-SV | |||
Operating voltage A1, A2 |
230 V ±10% |
110 V ±10% |
48 V ±10% |
Input voltage E1 – E7, EA |
230 V ±10% |
110 V ±10% |
48 V ±10% |
Measurement range |
0 V – 627 V | ||
Current transformer module, input |
0 V – 7.24 V | ||
Mains frequency |
50 Hz – 60 Hz | ||
Switching contacts |
250 V, 8 A | ||
Power consumption |
Max. 15 VA | ||
Ambient temperature |
-20 °C to +55 °C | ||
Output voltage load display |
5 V, max. 250 mA | ||
Display signal Q |
Serial data log ±12 V | ||
Feed voltage for encoder B+, B- |
10 V, at max. 10 mA | ||
Input voltage U+, U- |
0 mV – 20 mV | ||
Relative humidity |
5% − 85%, non-condensing |
Signal converter LIS-FC
LIS-FC | |||
Operating voltage A1, A2 |
230 V ±10% |
110 V ±10% |
48 V ±10% |
Mains frequency |
50 Hz – 60 Hz | ||
Power consumption |
approx. 4 VA | ||
Ambient temperature |
-20 °C to +55 °C | ||
Feed voltage for encoder B+, B- |
10 V, at max. 10 mA | ||
Input voltage U+, U- |
0 mV – 12 mV | ||
Output voltage F |
±12 V | ||
Output frequency F |
500 Hz – 30 kHz |