With this parameter you set the time-delayed switching on of the hoists in order to prevent a simultaneous high start-up current in the hoist motors. The parameter can be set with the values 0, 1 and 2.
Value |
Meaning |
0 |
Fast lifting speed without additional time delay |
1 |
0.5 s time delay |
2 |
1 s time delay |
Select parameter P 5.7 with
the arrow buttons.
● The parameter is opened.
Hold Enter pressed until “Code”
appears in the display.
Hold Enter pressed.
Enter code 1443.
Press Enter briefly.
Depending on area of use, select the following
setting with the arrow buttons:
Mode of operation |
Device 1 |
Device 2 |
1 hoist |
0 |
- - - |
2 hoists working in parallel |
1 |
1 |
Operation on a twin hoist |
1 |
2 |
Press Enter briefly.