P 4.5 Setting the load-controlled switching point on the current transformer module

In this parameter you set the load-controlled switching point for the total load in the range from 0% to 110% of the maximum load capacity. The value can be set in 2% steps.

In contrast to parameter P 4.40, the load-controlled switching point is not implemented through the output TxD - EA on the LIS-SV, but rather through the external current transformer module. If the set value is exceeded, the relay switches on the circuit board of the current transformer module.

This load-controlled switching point is used to switch functions potential-free.

The set value always refers to the setting of the maximum load capacity under P 0.0.

 

*   Select parameter P 4.5 with the arrow buttons.

*   Press Enter briefly.

●   The parameter is opened and the current saved value is displayed.

*   Set the desired value between 0% and 110% of the maximum load capacity of the crane.

*   Press Enter briefly.

●   The value is saved.