P 4.0 Setting the switching point of the overload protection for the total load of the crane

In this parameter you set the switching point for the overload protection of the total load of the crane. The setting is entered as a percentage lying between 0% and 110% of the entered maximum load capacity of the crane. The value can be set in 2% steps.

With multiple hoists, the entered value must be identical for all hoists, since the overload protection is for the total load and thus the load of the crane. All hoists switch off accordingly at the point the entered value is exceeded and the overload protection goes into overload status. At the same time, the LIS-SV displays the currently measured load and flashes once per second.

The set value always refers to the setting of the maximum load capacity under P 0.0.

 

*   Select parameter P 4.0 with the arrow buttons.

*   Press Enter briefly.

●   The parameter is opened.

*   Set the value between 0% and 110% of the maximum load capacity of the crane.

*   Press Enter briefly.

●   The value is saved.