If the LIS-SV is not working or functions other than as expected, a malfunction on the LIS-SV may be the cause.
In the event of malfunctions on the LIS-SV:
Malfunctions on the LIS-SV are indicated by error messages on this display.
Error message |
Fault |
Remedy | |
Err 0 |
Do not exceed the maximum load capacity. P 1.0 greater than P 0.0 or P 0.0 greater than the sum of P 1.0 + P 2.0 + P 3.0 |
Check P 0.0, P 1.0 and, if necessary, P 2.0 and P 3.0. | |
Err 1 |
The zero point frequency or gain factor for the device's own hoist is not set. |
Check P 1.3 and P 1.4. A value greater than 0 must be set. Carry out a precise setting using P 1.1 and P 1.2. | |
Err 2 |
The zero point frequency or gain factor for the hoist at input F2 is not set, although a load capacity was entered in P 2.0. |
Check P 2.3 and P 2.4. A value greater than 0 must be set. Carry out a precise setting using P 2.1 and P 2.2. | |
Err 3 |
The zero point frequency or gain factor for the hoist at input F3 is not set, although a load capacity was entered in P 3.0. |
Check P 3.3 and P 3.4. A value greater than 0 must be set. Carry out a precise setting using P 3.1 and P 3.2. | |
Err 4 |
Current correction factor was not entered. |
Set parameter P 5.6 according to the current range of the current transformer module. | |
Err 6 |
Frequency in the zero point is less than 0.100 kHz. |
Check input F1. | |
Err 5, Err 9 |
Error in the data transfer. |
Restart of the software. If this is unsuccessful, the LIS-SV must be replaced. | |
Err 8 |
Error during saving of data. |
Replace the LIS-SV. | |
F1 |
The frequency at input F1 is smaller than the saved value for the zero point. |
Use P 7.1 to check whether the frequency is detected and, if necessary, carry out a zero point adjustment with empty hook. | |
Value of the zero point frequency is incorrect due to, for example, performing the measurement with a test load in the hook. |
Perform the measurement of the zero point frequency again with empty hook. | ||
Measurement bolt is defective. |
Check measurement bolt and replace if necessary. | ||
LIS-SV power pack is faulty. |
Replace the LIS-SV. | ||
F2 |
The frequency at input F2 is smaller than the saved value. |
Check connection between F1 and F2. Use P 7.2 to check whether the frequency is detected and, if necessary, carry out a zero point adjustment with empty hook. | |
F3 |
The frequency at input F3 is smaller than the saved value. |
Check connection between F1 and F3. Use P 7.3 to check whether the frequency is detected and, if necessary, carry out a zero point adjustment with empty hook. | |
00.00 |
Overload switch-off with empty hook. |
Check P 4.0/P 4.1/P 4.2/P 4.3
and set to 110%. | |
[ no ] |
The PIN or code was entered 4 times incorrectly. |
Request a returns form through ABUS Service and send it in to unlock the device. | |
Test not OK |
Malfunction of the LIS-SV |
Request a returns form through ABUS Service and send it in. | |
- - H2 |
Not
an error message but a status message: “One of the other hoists has
stopped”. |
If this is not the case: check signals at input E5. | |
Switch-off during fast lifting speed, display shows “ABUS” |
Voltage drop. |
Read out P 7.61. Check power line and boost if necessary. | |
Value greater than 110% of load capacity, flashing |
For overload the display flashes in 1 Hz cycles and for overcurrent twice per second at 0.5 Hz. |
For overload: Set down the load. For overcurrent: | |
Undefined sign on the load display |
The Q and GND wires are interchanged. |
Check the assignment. | |
Power line faulty. |
Check the power line. | ||
Value flashes |
Motor current
display |
Motor mechanically hampered, e.g. by the brake not opening, a blocked gear unit or defective ball bearing. Contactor faulty, loose connection, faulty current collector. | |
Display is dark |
Display operating voltage has dropped out. Plug contacts between main and display circuit boards oxidised by aggressive ambient conditions. LIS-SV power pack is faulty. |
Replace the LIS-SV. |
Error message |
Fault |
Remedy |
Err 0 |
P 1.0 is not set. |
Enter the maximum load capacity of the device's own hoist in P 1.0. |
Err 1 |
The zero point frequency or gain factor of the device's own hoist is not set. |
Check P 1.3 and P 1.4. A value greater than 0 must be set. Carry out a precise setting using P 1.1 and P 1.2. |
Err 2 |
P 2.0 is not set, although P 2.3/P 2.4 is greater than 0. |
Enter the maximum load capacity for the hoist at input F2 in P 2.0. |
Err 3 |
P 3.0 is not set, although P 3.3/P 3.4 is greater than 0. |
Enter the maximum load capacity for the hoist at input F3 in P 3.0. |
Err 4 |
Current correction factor was not entered. |
Set parameter P 5.6 according to the current range of the current transformer module. |
Err 7 |
When setting with test load, it was detected that the frequency difference to the zero point frequency was too small. |
Repeat the setting with a larger test load. Replace measurement bolt if necessary. |
F1 |
The zero point adjustment was carried out with load in the hook (e.g. lifting tackle). |
Perform the zero point adjustment with empty load hook. |
[ no ] |
The PIN or code was entered 4 times incorrectly. |
Request a returns form through ABUS Service and send it in to unlock the device. |