Connect according to the wiring
diagram.
Lift the test load.
Compare the value that the
LIS-SV shows on the load display or in the corresponding parameters for the load
display (P 7.00, P 7.01, P 7.02, P 7.03).
If the deviation is greater than -5% to +5%, the corresponding parameters must be adjusted!
In this case, it is necessary to adjust the respective parameters of the respective hoist, or new measurements must be made. See P 1.2/P 2.2/P 3.2 Setting with test load.