If the LIS-SE is not working or functions other than as expected, a malfunction on the LIS-SE may be the cause.
In the event of malfunctions on the LIS-SE:
Malfunctions on the LIS-SE are indicated by error messages on the display.
Error messages |
Fault |
Remedy |
Err 1 |
Current correction factor was not entered. |
Enter current correction factor under parameter P 1.3. |
Err 2 |
Maximum load capacity was not entered. |
Enter the maximum load capacity under parameter P 0.1. |
Err 3 |
LIS-SE is not set. |
Enter the setting with test load (P 2.3). |
Err 6 |
Displayed in parameter P 2.3 in the case of insufficient test load or if there are errors in the settings or connections. |
Increase test load to at least 40% of the maximum load capacity and perform the setting with test load again (P 2.3). |
Err 7 |
Settings were not entered correctly; for example, the Lift button being released in teach-in mode in P 2.3 before the measurement had been completed. |
Repeat the settings. |
Err 8 |
Error during saving of the data |
Replace the LIS-SE. |
Err 9 |
Error during reading of the data. |
Hold Enter pressed until the error message disappears. Otherwise, replace the LIS-SE. |
[ no ] |
The PIN or code was entered 4 times incorrectly. |
Request a returns form through ABUS Service and send it in to unlock the device. |
− − 17 |
Inching counter has triggered. |
Hold the lowering button pressed for at least 3 s. |
U_I |
The calculated rotating field power is less than 10 W. |
Faulty contactors |
Wiring error. | ||
Check settings | ||
Insufficient voltage at input 1 L01 | ||
00.00 |
Overload switch-off or inching counter if, without acknowledging the message by lowering, the voltage was switched off and then back on again. |
Hold the lowering button pressed for at least 3 s. |
Overload - flashes once per second |
Overload lifted |
Set down load and reduce the load. |
Overload switch-off has triggered although no overload was lifted. |
Worn contactors | |
Voltage drop | ||
Power line dimensions too small. | ||
Start-up current too high. | ||
Brake does not release | ||
Wrong motor type set | ||
- - H2 |
Switch-off of a hoist in joint operation, e.g. when reaching a limit switch, caused by lifting tackle of unequal length, asymmetrical slinging points or overload of one of the hoists. |
If this is not the case: check signals at input E5. |
Test not OK |
Malfunction of the LIS-SE |
Request a returns form through ABUS Service and send it in. |
Switch-off during fast lifting speed with “Overload” in display (flashes once per second). |
Voltage drop. |
Read out P 3.41. Check power line and boost if necessary. Check main contactors. |
Value over 110% of load capacity (flashes once per second) |
Overload |
Set down the load. |
Value flashes twice per second |
Motor current display Switch-off of main contactors for 60 s. |
Motor mechanically hampered, e.g. by the brake not opening, a blocked gear unit or defective ball bearing. Contactor faulty, loose connection, faulty current collector. |
Display is dark |
Display operating voltage has dropped out. |
LIS-SE power pack is faulty. |