The ceiling-mounted bracket 2LP/M16 or M20 is clamped with two flange clamps on the lower flange of an I-beam.
|
| |
|
Threaded rod |
Articulated girder |
|
The figures show the installation of a ceiling-mounted bracket 2LP/M16 or M20 with projecting threaded rod (with normal suspension, short suspension and normal stiffener). The installation of a ceiling-mounted bracket 2LP/M16 with bolted-on articulated girder (with normal stiffener, inclined suspension, inclined stiffener and V-suspension) does not differ significantly from this. |
|
The figures show the installation of a ceiling-mounted bracket 2LP/M16 with bolted-on articulated girder. The installation of ceiling-mounted bracket 2LP/M20 does not essentially differ. | |
|
|
The installation of the ceiling-mounted bracket 4LP/M20 is described in the product manual "Installing the ceiling-mounted bracket 4LP/M20 and craneway suspension M20". |
This section only applies to the ceiling-mounted bracket 2LP/M16 with bolted-on articulated girder (with normal stiffener, inclined suspension, inclined stiffener and V-suspension)
On every ceiling-mounted bracket 2LP/M16 with articulated girder:
The articulated girders can be mounted lengthwise or crosswise to the ceiling-mounted bracket 4LP/M20 as appropriate for the alignment of the supporting structure.
|
Ceiling-mounted bracket |
|
|
| |
|
|
Articulated girder |
Insert M16x35 rib screw through
articulated girder.
Insert articulated girder with rib
screw in ceiling-mounted bracket.
Screw the M16 rib nut loosely onto the
rib screw from the back.
Shift the articulated girder
lengthwise or crosswise to the ceiling-mounted bracket as necessary.
Screw the rib nut on. 300 Nm.
Two per ceiling-mounted bracket 2LP/M16 or M20:
|
Clamping plate |
Clamping bracket with head plate |
|
| |
|
Hexagon head screw |
Retaining plate |
Slide the head plate, clamping bracket
and retaining plate onto the M16x30 hexagon head screw.
Push the hexagon head screw through
the ceiling-mounted bracket.
Insert the clamping plate from
below.
Screw the M16 rib nut loosely on the
hexagon head screw.
|
Clamping bracket |
Lug |
|
| |
|
Retaining plate |
|
Turn clamping bracket: the lug of the
clamping bracket should clamp in the opening of the retaining plate.
This section only applies if the flange of the I-beam is thicker than 20 mm.
Two per ceiling-mounted bracket 2LP/M16 or M20:
|
Clamping plate |
Hexagon head screw |
|
| |
|
Retaining plate for thick flange |
Clamping bracket with head plate |
Slide head plate, clamping bracket and retaining
plate for thick flange onto M16 hexagon head screw.
Push the hexagon head screw through
the ceiling-mounted bracket.
Insert the clamping plate from
below.
Screw the M16 rib nut loosely on the
hexagon head screw.
|
Clamping bracket |
Lug |
|
| |
|
Retaining plate for thick flange |
|
On every ceiling-mounted bracket 2LP/M16 or M20:
|
|
Where and at what intervals the ceiling-mounted brackets are fixed to the supporting structure is specified in the planning documents. |
The specified dimensions, positions and clearances must be followed exactly.
|
|
Flange clamps |
|
| |
Push the ceiling-mounted bracket with
flange clamps onto the I-beam.
|
Ceiling-mounted bracket centred in relation to HB profile rail |
Ceiling-mounted bracket perpendicular to HB profile rail |
|
| |
|
Later-installed HB profile rail |
Suspension distance LB |
Position the ceiling-mounted bracket
so that it is exactly centred in relation to the later-installed HB profile
rail.
This is necessary so that the HB profile rail can later be aligned.
|
|
Screw on the M16 rib nuts (2x)
initially hand-tight.
The rib nuts will later be tightened to the correct torque (after aligning the HB profile rail).
If final alignment of the ceiling-mounted bracket 2LP/M16 or M20 can now be done:
Screw the rib nuts tight.
200 Nm.