In some situations, it may be necessary to overrun a set switching point (upper or lower).
Move to the switching point to
be overrun until the load hook stops.
If the load hook is within about 10 cm of the switching point, the following sequence overruns the set switching point. Beyond this range, this sequence is used to set a switching point.
Control cable |
Bayonet nut |
| |
Teach-in module |
|
Remove the pendant control.
Insert the teach-in module.
Wait at least 5 s.
Remove the teach-in module.
Only with pendant control with
teach-in button: Instead of inserting the teach-in module, press and hold the
teach-in button for 5 seconds.
Only with ABURemote AC with
teach-in: Instead of inserting the teach-in module, press and hold the
“teach-in” direct access button (T with arrow) for 5 seconds.
Control cable |
Bayonet coupling |
| |
Emergency stop button |
Pendant control |
Only with teach-in module:
Insert pendant control.
Only with teach-in module:
Unlock emergency stop button.
Move the chain up or down over
the set switching point.
● The set switching point has been overrun.