If necessary, all the set switching points can be deleted.
For this, the electronic hoist limit switch must be referenced again. During referencing, the switching points can be deleted as well.
Overview of referencing the hoist limit switch and deleting the switch points: ─ Switch off the chain hoist, wait 30 seconds, then switch on the chain hoist again. ─ Only with teach-in module: Remove the pendant control, plug in the teach-in module, wait 30 seconds, then remove the teach-in module and insert the pendant control. Only with pendant control with teach-in button: Press teach-in button for 30 seconds. Only with ABURemote AC with teach-in: Press “teach-in” direct access button (T with arrow) for 30 seconds. ─ Move to the reference point. This should be as high up as possible without the load hook coming into contact with the housing. ─ The last movement command before teach-in must be the “Lift” button. ─ Only with teach-in module: Remove the pendant control, plug in the teach-in module, wait 5 seconds, then remove the teach-in module and insert the pendant control. Only with pendant control with teach-in button: Press teach-in button for 5 seconds. Only with ABURemote AC with teach-in: Press “teach-in” direct access button (T with arrow) for 5 seconds. ─ The hoist limit switch is referenced again and the switching points are deleted. |
For a detailed description of the process, see page 57.