Installing the cross-type limit switch

 

Only with cross-type limit switch

This section only applies if the wire rope hoist has a cross-type limit switch in the trolley travel direction.

Where and for which travel limit the cross-type limit switch is designed is specified on the wiring diagram.

 

Installing the cross-type limit switch

Warnung Vorsicht

Danger due to malfunction!

If the cross-type limit switch is screwed on too tightly, the parts on the inside can become jammed and no longer function properly.

The tightening torque of 3 Nm must be precisely observed.

 

Locking washer

Hexagonal nut

Fillister-head screw M5x50

Mounting bracket

*   Screw the mounting bracket onto the cross-type limit switch with the fillister-head screws M5x50 (2x).

*   Screw on the mounting bracket using locking washers and M5 hexagonal nuts (2x). 3 Nm.

 

 

Installing the cross-type limit switch on the trolley towing arm

The cross-type limit switch is normally installed on the trolley towing arm.

 

Trolley towing arm

Pipe clamp

 

Cross-type limit switch

*   Turn the cross-type limit switch to position 0.

The position of the cross-type limit switch is marked with an arrow that can be rotated further, depending on the switching state.

*   Move the cross-type limit switch onto the square tube in such a way that the switching lug activates the cross-type limit switch.

*   Screw the cross-type limit switch with pipe clamps (2x) tightly.15 Nm.

 

 

Connecting the cross-type limit switch

*   Route the connection cable (round cable or flat cable) from the cross-type limit switch to the panel.

*   Route the connection cable with cable fitting into the panel.

*   If necessary, connect the connection cable to a coupler plug or connector.

*   Fasten connection cable with cable grips, cable ties and adhesive clips.