This section only applies if the wire rope hoist has a cross-type limit switch in the trolley travel direction.
Where and for which travel limit the cross-type limit switch is designed is specified on the wiring diagram.
Danger due to malfunction! If the cross-type limit switch is screwed on too tightly, the parts on the inside can become jammed and no longer function properly. The tightening torque of 3 Nm must be precisely observed. |
Locking washer |
Hexagonal nut |
Fillister-head screw M5x50 |
Mounting bracket |
Screw the mounting bracket onto the cross-type limit switch with the fillister-head screws M5x50 (2x).
Screw on the mounting bracket using locking washers and M5 hexagonal nuts (2x). 3 Nm.
The cross-type limit switch is normally installed on the trolley towing arm.
Trolley towing arm |
Pipe clamp |
|
Cross-type limit switch |
Turn the cross-type limit switch to position 0.
The position of the cross-type limit switch is marked with an arrow that can be rotated further, depending on the switching state.
Move the cross-type limit switch onto the square tube in such a way that the switching lug activates the cross-type limit switch.
Screw the cross-type limit switch with pipe clamps (2x) tightly.15 Nm.
Route the connection cable (round cable or flat cable) from the cross-type limit switch to the panel.
Route the connection cable with cable fitting into the panel.
If necessary, connect the connection cable to a coupler plug or connector.
Fasten connection cable with cable grips, cable ties and adhesive clips.