The pictures show the procedure on a GM 1000 modular wire rope hoist. The procedure on GM 800 does not differ significantly from this.
On both flange plates:
|
Flange plate |
|
|
| |
|
Hexagon head screws |
|
Check the hexagon head screws. They must be tightened to
85 Nm.
|
Size |
Screws |
Number |
|
GM 800 |
M12x40 |
10x |
|
GM 1000 |
M12x40 |
15x |
If the hexagon head screws have not been screwed in properly: Tighten
the hexagon head screws. 85 Nm.