For repairs or replacement, it may be necessary to reconnect the drive.
The pictures show the procedure on a GM 1000 modular wire rope hoist. The procedure on GM 800 does not differ significantly from this.
Pin multipoint connector for drive and brake |
|
| |
|
Bush multipoint connector for drive and brake |
Open the housing cover.
Plug-in connection |
Cable bushing |
| |
Screening clamp connection |
Connection cable |
Fasten the connection cable to the screening clamp connection using
cable ties.
Lay the plug-in connections
and connection cable in the connector housing.
Close the housing cover.
Brake |
|
| |
Protective conductor |
Motor winding |
Connect the lead end of the protective conductor onto the terminal
with the protection conductor symbol.
Connect the brake to the “Br” terminals.
Connect the winding of the motor to the terminals W, V and U.