Connecting the drive

 

For repairs or replacement, it may be necessary to reconnect the drive.

The pictures show the procedure on a GM 1000 modular wire rope hoist. The procedure on GM 800 does not differ significantly from this.

 

Connecting the drive

Pin multipoint connector for drive and brake

 

 

Bush multipoint connector for drive and brake

*   Open the housing cover.

*   Insert the bush multipoint connector for the drive and brake on the pin multipoint connector on the drive.

 

 

Plug-in connection

Cable bushing

Screening clamp connection

Connection cable

*   Push the front end of the connection cable (where the sheathing around the shield has been removed) into the screening clamp connection.

*   Fasten the connection cable to the screening clamp connection using cable ties.

*   Lay the plug-in connections and connection cable in the connector housing.

*   Close the housing cover.

 

 

Connecting wires to the plug-in connection

Brake

 

Protective conductor

Motor winding

*   Connect the lead end of the protective conductor onto the terminal with the protection conductor symbol.

*   Connect the brake to the “Br” terminals.

*   Connect the winding of the motor to the terminals W, V and U.