Technical data

Electrical connection

 

Drive DL 80 and DL 112

Drive DL 140

Operating voltage

380 - 415 V

380 – 415 V

Mains frequency

50 Hz

50 Hz

Duty cycle

50 %

50 %

Switching rate

240 c/h

240 c/h

Rated power

0.06 / 0.25 kW

0.09 / 0.37 kW

Start-up current I A

0.79 / 4.5 A

1.02 / 5.0 A

cos phi A

0.75 / 0.9

0.8 / 0.9

Rated current I N

0.44 / 0.93 A

0.60 / 1.0 A

cos phi N

0.6 / 0.7

0.7 / 0.8

 

Electrical connection brake

Drive

Voltage

Electrical power

DL 80 / 112

195 VDC

21 W

DL 140

195 VDC

25 W

 

 

Ambient conditions for operation:

 

 

Ambient temperature (for normal operation)

- 10 °C and + 40 °C

Ambient temperature (for reduced duty cycle)

+ 40 °C to 80 °C

 

Noise emissions:

Trolley

Sound pressure level LP, m dB(A) at distance of 4 m

Sound pressure level LW, m dB(A)

DL 80 / DL 112

67

84

DL 140

64

81

Table: Noise emissions based on DIN 45635, Part 61 following the substitution process with an acoustic power source

 