Observe the product manuals! In addition to the points described here, all information in the section “Technical data” in the other supplied product manuals and in the appropriate crane test log book in the corresponding data sheets also applies. |
Normal ambient conditions during operation:
|
Range |
Ambient temperature |
-10 °C to +40 °C |
Height position |
Up to 1000 m above sea level |
Ambient conditions for a complete crane including control.
Operation in other ambient conditions (e.g. at a higher ambient temperature) is in many cases possible. For questions regarding individual on-site conditions in the building (e.g. duration and type of heat and its influence on the crane), ABUS Service will gladly be of assistance. See ABUS Service.
This section only applies to travel drives and hoist drives.
|
Range | |
Ambient temperature |
-10 °C to +40 °C | |
Ambient temperature (for reduced duty cycle) |
+40 °C to +65 °C | |
Ambient conditions exclusively for travel and hoist drives.
Travel and hoist drives can also be used at a reduced duty cycle and switching rate, even at an ambient temperature of +40°C to +65°C.
Operation at higher ambient temperatures:
Duty cycle according to type plate |
Modified duty cycle at ambient temperatures of +40 °C to +65 °C |
60 % |
30 % |
50 % |
25 % |
40 % |
20 % |
Switching rate according to type plate |
Modified switching rate at ambient temperatures of +40 °C to +65 °C |
420 |
210 |
360 |
180 |
300 |
150 |
240 |
120 |
180 |
90 |
At ambient temperatures of +40°C
to +65°C, reduce the duty cycle and switching rate according to the tables.
Operation at higher elevations:
At higher elevations, the crane will be less well cooled due to the reduced air pressure.
Reduce the duty cycle and
switching rate at higher elevations.