Noise level:
Trolley type |
Sound pressure level LP in dB (A) at a distance of 3 m |
Sound pressure level LW, m dB (A) |
E 100 |
66 |
83 |
E 130 |
67 |
84 |
E 160 |
67 |
84 |
E 200 |
60 |
77 |
AZP 130 |
63 |
80 |
AZP 160 |
60 |
77 |
AZP 200 |
63 |
80 |
AZP 280 |
60 |
77 |
Weights:
Trolley type |
Weight in kg |
E 100 |
11.3 |
E 130 |
16.3 |
E 160 |
19.5 |
E 200 |
27.8 |
AZP 130 |
21 |
AZP 160 |
30 |
AZP 200 |
40 |
AZP 280 |
60 |
Electrical data E 100:
Part number |
19496 | |
Operating voltage |
380 – 415 V |
440 – 480 V |
Frequency |
50 Hz |
60 Hz |
Travel speed m/min |
4 / 16 |
4.8 / 19.2 |
Duty cycle FEM |
50 % | |
Switching rate FEM c/h |
240 (at
3 m) | |
Rated power kW |
0.03 / 0.12 |
0.04 / 0.14 |
Motor speed rpm |
640 / 2670 |
790 / 3240 |
Start-up current A |
0.40 / 1.20 | |
Rated current A |
0.29 / 0.46 | |
cos phi A |
0.85 / 0.94 |
0.82 / 0.93 |
cos phi N |
0.67 / 0.85 |
0.64 / 0.85 |
Part number |
19497 | |
Operating voltage |
380 – 415 V |
440 – 480 V |
Frequency |
50 Hz |
60 Hz |
Travel speed m/min |
5 / 20 |
6 / 24 |
Duty cycle FEM |
50 % | |
Switching rate FEM c/h |
240 (at
3 m) | |
Rated power kW |
0.03 / 0.12 |
0.04 / 0.14 |
Motor speed rpm |
640 / 2670 |
790 / 3240 |
Start-up current A |
0.40 / 1.20 | |
Rated current A |
0.29 / 0.46 | |
cos phi A |
0.85 / 0.94 |
0.82 / 0.93 |
cos phi N |
0.67 / 0.85 |
0.64 / 0.85 |
Part number |
19498 | |
Operating voltage |
380 – 415 V |
440 – 480 V |
Frequency |
50 Hz |
60 Hz |
Travel speed m/min |
7 / 28 |
8.4 / 33.6 |
Duty cycle FEM |
50 % | |
Switching rate FEM c/h |
240 (at
3 m) | |
Rated power kW |
0.03 / 0.12 |
0.04 / 0.14 |
Motor speed rpm |
640 / 2670 |
790 / 3240 |
Start-up current A |
0.40 / 1.20 | |
Rated current A |
0.29 / 0.46 | |
cos phi A |
0.85 / 0.94 |
0.82 / 0.93 |
cos phi N |
0.67 / 0.85 |
0.64 / 0.85 |
Electrical data E 130:
Part number |
309356 | |
Operating voltage |
380 – 415 V |
440 – 480 V |
Frequency |
50 Hz |
60 Hz |
Travel speed m/min |
4 / 16 |
4.8 / 19.2 |
Duty cycle FEM |
50 % | |
Switching rate FEM c/h |
240 (at
3 m) | |
Rated power kW |
0.04 / 0.18 |
0.05 / 0.22 |
Motor speed rpm |
620 / 2690 |
780 / 3280 |
Start-up current A |
0.52 / 2.10 | |
Rated current A |
0.37 / 0.57 | |
cos phi A |
0.91 / 0.91 |
0.90 / 0.88 |
cos phi N |
0.75 / 0.85 |
0.71 / 0.86 |
Part number |
309358 | |
Operating voltage |
380 – 415 V |
440 – 480 V |
Frequency |
50 Hz |
60 Hz |
Travel speed m/min |
5 / 20 |
6 / 24 |
Duty cycle FEM |
50 % | |
Switching rate FEM c/h |
240 (at
3 m) | |
Rated power kW |
0.04 / 0.18 |
0.05 / 0.22 |
Motor speed rpm |
620 / 2690 |
780 / 3280 |
Start-up current A |
0.52 / 2.10 | |
Rated current A |
0.37 / 0.57 | |
cos phi A |
0.91 / 0.91 |
0.90 / 0.88 |
cos phi N |
0.75 / 0.85 |
0.71 / 0.86 |
Part number |
309359 | |
Operating voltage |
380 – 415 V |
440 – 480 V |
Frequency |
50 Hz |
60 Hz |
Travel speed m/min |
7 / 28 |
8.4 / 33.6 |
Duty cycle FEM |
50 % | |
Switching rate FEM c/h |
240 (at
3 m) | |
Rated power kW |
0.04 / 0.18 |
0.05 / 0.22 |
Motor speed rpm |
620 / 2690 |
780 / 3280 |
Start-up current A |
0.52 / 2.10 | |
Rated current A |
0.37 / 0.57 | |
cos phi A |
0.91 / 0.91 |
0.90 / 0.88 |
cos phi N |
0.75 / 0.85 |
0.71 / 0.86 |
Electrical data E 160:
Part number |
306388 | |
Operating voltage |
380 – 415 V |
440 – 480 V |
Frequency |
50 Hz |
60 Hz |
Travel speed m/min |
5 / 20 |
6 / 24 |
Duty cycle FEM |
50 % | |
Switching rate FEM c/h |
240 (at
3 m) | |
Rated power kW |
0.06 / 0.28 |
0.07 / 0.34 |
Motor speed rpm |
595 / 2770 |
755 / 3320 |
Start-up current A |
0.57 / 3.20 | |
Rated current A |
0.35 / 0.83 | |
cos phi A |
0.82 / 0.92 |
0.79 / 0.89 |
cos phi N |
0.65 / 0.84 |
0.63 / 0.84 |
Part number |
308956 | |
Operating voltage |
380 – 415 V |
440 – 480 V |
Frequency |
50 Hz |
60 Hz |
Travel speed m/min |
7 / 28 |
8.4 / 33.6 |
Duty cycle FEM |
50 % | |
Switching rate FEM c/h |
240 (at
3 m) | |
Rated power kW |
0.06 / 0.28 |
0.07 / 0.34 |
Motor speed rpm |
595 / 2770 |
755 / 3320 |
Start-up current A |
0.57 / 3.20 | |
Rated current A |
0.35 / 0.83 | |
cos phi A |
0.82 / 0.92 |
0.79 / 0.89 |
cos phi N |
0.65 / 0.84 |
0.63 / 0.84 |
Electrical data E 200:
Part number |
17856 | |
Operating voltage |
380 – 415 V |
440 – 480 V |
Frequency |
50 Hz |
60 Hz |
Travel speed m/min |
5 / 20 |
6 / 24 |
Duty cycle FEM |
50 % | |
Switching rate FEM c/h |
240 (at
3 m) | |
Rated power kW |
0.10 / 0.48 |
0.12 / 0.58 |
Motor speed rpm |
550 / 2760 |
735 / 3370 |
Start-up current A |
0.92 / 5.90 | |
Rated current A |
0.53 / 1.59 | |
cos phi A |
0.71 / 0.91 |
0.64 / 0.88 |
cos phi N |
0.66 / 0.80 |
0.65 / 0.83 |
Part number |
17857 | |
Operating voltage |
380 – 415 V |
440 – 480 V |
Frequency |
50 Hz |
60 Hz |
Travel speed m/min |
7 / 28 |
8.4 / 33.6 |
Duty cycle FEM |
50 % | |
Switching rate FEM c/h |
240 (at
3 m) | |
Rated power kW |
0.10 / 0.48 |
0.12 / 0.58 |
Motor speed rpm |
550 / 2760 |
735 / 3370 |
Start-up current A |
0.92 / 5.90 | |
Rated current A |
0.53 / 1.59 | |
cos phi A |
0.71 / 0.91 |
0.64 / 0.88 |
cos phi N |
0.66 / 0.80 |
0.65 / 0.83 |
Electrical data AZP 130:
Part number |
309361 | |
Operating voltage |
380 – 415 V |
440 – 480 V |
Frequency |
50 Hz |
60 Hz |
Travel speed m/min |
5 / 20 |
6 / 24 |
Duty cycle FEM |
50 % | |
Switching rate FEM c/h |
240 (at
3 m) | |
Rated power kW |
0.04 / 0.18 |
0.05 / 0.22 |
Motor speed rpm |
620 / 2690 |
780 / 3280 |
Start-up current A |
0.52 / 2.10 | |
Rated current A |
0.37 / 0.57 | |
cos phi A |
0.91 / 0.91 |
0.90 / 0.88 |
cos phi N |
0.75 / 0.85 |
0.71 / 0.86 |
Part number |
309363 | |
Operating voltage |
380 – 415 V |
440 – 480 V |
Frequency |
50 Hz |
60 Hz |
Travel speed m/min |
5 / 20 |
6 / 24 |
Duty cycle FEM |
50 % | |
Switching rate FEM c/h |
240 (at
3 m) | |
Rated power kW |
0.06 / 0.28 |
0.07 / 0.34 |
Motor speed rpm |
595 / 2770 |
755 / 3320 |
Start-up current A |
0.57 / 3.20 | |
Rated current A |
0.35 / 0.83 | |
cos phi A |
0.82 / 0.92 |
0.79 / 0.89 |
cos phi N |
0.65 / 0.84 |
0.63 / 0.84 |
Part number |
309362 | |
Operating voltage |
380 – 415 V |
440 – 480 V |
Frequency |
50 Hz |
60 Hz |
Travel speed m/min |
7.5 / 30 |
9 / 36 |
Duty cycle FEM |
50 % | |
Switching rate FEM c/h |
240 (at
3 m) | |
Rated power kW |
0.04 / 0.18 |
0.05 / 0.22 |
Motor speed rpm |
620 / 2690 |
780 / 3280 |
Start-up current A |
0.52 / 2.10 | |
Rated current A |
0.37 / 0.57 | |
cos phi A |
0.91 / 0.91 |
0.90 / 0.88 |
cos phi N |
0.75 / 0.85 |
0.71 / 0.86 |
Part number |
308955 | |
Operating voltage |
380 – 415 V |
440 – 480 V |
Frequency |
50 Hz |
60 Hz |
Travel speed m/min |
7.5 / 30 |
9 / 36 |
Duty cycle FEM |
50 % | |
Switching rate FEM c/h |
240 (at
3 m) | |
Rated power kW |
0.06 / 0.28 |
0.07 / 0.34 |
Motor speed rpm |
595 / 2770 |
755 / 3320 |
Start-up current A |
0.57 / 3.20 | |
Rated current A |
0.35 / 0.83 | |
cos phi A |
0.82 / 0.92 |
0.79 / 0.89 |
cos phi N |
0.65 / 0.84 |
0.63 / 0.84 |
Part number |
306387 | |
Operating voltage |
380 – 415 V |
440 – 480 V |
Frequency |
50 Hz |
60 Hz |
Travel speed m/min |
10 / 40 |
12 / 48 |
Duty cycle FEM |
50 % | |
Switching rate FEM c/h |
240 (at
3 m) | |
Rated power kW |
0.06 / 0.28 |
0.07 / 0.34 |
Motor speed rpm |
595 / 2770 |
755 / 3320 |
Start-up current A |
0.57 / 3.20 | |
Rated current A |
0.35 / 0.83 | |
cos phi A |
0.82 / 0.92 |
0.79 / 0.89 |
cos phi N |
0.65 / 0.84 |
0.63 / 0.84 |
Part number |
79559 | |
Operating voltage |
380 – 415 V |
440 – 480 V |
Frequency |
50 Hz |
60 Hz |
Travel speed m/min |
10 / 40 |
12 / 48 |
Duty cycle FEM |
50 % | |
Switching rate FEM c/h |
240 (at
3 m) | |
Rated power kW |
0.08 / 0.37 |
0.095 / 0.44 |
Motor speed rpm |
545 / 2760 |
720 / 3355 |
Start-up current A |
0.75 / 4.30 | |
Rated current A |
0.57 / 1.05 | |
cos phi A |
0.80 / 0.92 |
0.74 / 0.90 |
cos phi N |
0.65 / 0.78 |
0.58 / 0.82 |
Part number |
8321 | |
Operating voltage |
380 – 415 V |
440 – 480 V |
Frequency |
50 Hz |
60 Hz |
Travel speed m/min |
12.5 / 50 |
15 / 60 |
Duty cycle FEM |
40 % | |
Switching rate FEM c/h |
240 (at
3 m) | |
Rated power kW |
0.06 / 0.28 |
0.07 / 0.34 |
Motor speed rpm |
595 / 2770 |
755 / 3320 |
Start-up current A |
0.57 / 3.20 | |
Rated current A |
0.35 / 0.83 | |
cos phi A |
0.82 / 0.92 |
0.79 / 0.89 |
cos phi N |
0.65 / 0.84 |
0.63 / 0.84 |
Part number |
79560 | |
Operating voltage |
380 – 415 V |
440 – 480 V |
Frequency |
50 Hz |
60 Hz |
Travel speed m/min |
12.5 / 50 |
15 / 60 |
Duty cycle FEM |
40 % | |
Switching rate FEM c/h |
240 (at
3 m) | |
Rated power kW |
0.08 / 0.37 |
0.095 / 0.44 |
Motor speed rpm |
545 / 2760 |
720 / 3355 |
Start-up current A |
0.75 / 4.30 | |
Rated current A |
0.57 / 1.05 | |
cos phi A |
0.80 / 0.92 |
0.74 / 0.90 |
cos phi N |
0.65 / 0.78 |
0.58 / 0.82 |
Electrical data AZP 160:
Part number |
126969 | |
Operating voltage |
380 – 415 V |
440 – 480 V |
Frequency |
50 Hz |
60 Hz |
Travel speed m/min |
5 / 20 |
6 / 24 |
Duty cycle FEM |
50 % | |
Switching rate FEM c/h |
240 (at
3 m) | |
Rated power kW |
0.10 / 0.48 |
0.12 / 0.58 |
Motor speed rpm |
550 / 2760 |
735 / 3370 |
Start-up current A |
0.92 / 5.90 | |
Rated current A |
0.53 / 1.59 | |
cos phi A |
0.71 / 0.91 |
0.64 / 0.88 |
cos phi N |
0.66 / 0.80 |
0.65 / 0.83 |
Part number |
126970 | |
Operating voltage |
380 – 415 V |
440 – 480 V |
Frequency |
50 Hz |
60 Hz |
Travel speed m/min |
7.5 / 30 |
9 / 36 |
Duty cycle FEM |
50 % | |
Switching rate FEM c/h |
240 (at
3 m) | |
Rated power kW |
0.10 / 0.48 |
0.12 / 0.58 |
Motor speed rpm |
550 / 2760 |
735 / 3370 |
Start-up current A |
0.92 / 5.90 | |
Rated current A |
0.53 / 1.59 | |
cos phi A |
0.71 / 0.91 |
0.64 / 0.88 |
cos phi N |
0.66 / 0.80 |
0.65 / 0.83 |
Part number |
126971 | |
Operating voltage |
380 – 415 V |
440 – 480 V |
Frequency |
50 Hz |
60 Hz |
Travel speed m/min |
10 / 40 |
12 / 48 |
Duty cycle FEM |
50 % | |
Switching rate FEM c/h |
240 (at
3 m) | |
Rated power kW |
0.10 / 0.48 |
0.12 / 0.58 |
Motor speed rpm |
550 / 2760 |
735 / 3370 |
Start-up current A |
0.92 / 5.90 | |
Rated current A |
0.53 / 1.59 | |
cos phi A |
0.71 / 0.91 |
0.64 / 0.88 |
cos phi N |
0.66 / 0.80 |
0.65 / 0.83 |
Part number |
126972 | |
Operating voltage |
380 – 415 V |
440 – 480 V |
Frequency |
50 Hz |
60 Hz |
Travel speed m/min |
12.5 / 50 |
15 / 60 |
Duty cycle FEM |
40 % | |
Switching rate FEM c/h |
240 (at
3 m) | |
Rated power kW |
0.10 / 0.48 |
0.12 / 0.58 |
Motor speed rpm |
550 / 2760 |
735 / 3370 |
Start-up current A |
0.92 / 5.90 | |
Rated current A |
0.53 / 1.59 | |
cos phi A |
0.71 / 0.91 |
0.64 / 0.88 |
cos phi N |
0.66 / 0.80 |
0.65 / 0.83 |
Part number |
126973 | |
Operating voltage |
380 – 415 V |
440 – 480 V |
Frequency |
50 Hz |
60 Hz |
Travel speed m/min |
15 / 60 |
18 / 72 |
Duty cycle FEM |
40 % | |
Switching rate FEM c/h |
150 (at
1 Am) | |
Rated power kW |
0.10 / 0.48 |
0.12 / 0.58 |
Motor speed rpm |
550 / 2760 |
735 / 3370 |
Start-up current A |
0.92 / 5.90 | |
Rated current A |
0.53 / 1.59 | |
cos phi A |
0.71 / 0.91 |
0.64 / 0.88 |
cos phi N |
0.66 / 0.80 |
0.65 / 0.83 |
Electrical data AZP 200:
Part number |
90156 | |
Operating voltage |
380 – 415 V |
440 – 480 V |
Frequency |
50 Hz |
60 Hz |
Travel speed m/min |
5 / 20 |
6 / 24 |
Duty cycle FEM |
50 % | |
Switching rate FEM c/h |
240 (at
3 m) | |
Rated power kW |
0.14 / 0.65 |
0.17 / 0.78 |
Motor speed rpm |
620 / 2750 |
775 / 3350 |
Start-up current A |
1.45 / 8.10 | |
Rated current A |
0.68 / 1.68 | |
cos phi A |
0.80 / 0.82 |
0.75 / 0.77 |
cos phi N |
0.67 / 0.86 |
0.66 / 0.87 |
Part number |
90157 | |
Operating voltage |
380 – 415 V |
440 – 480 V |
Frequency |
50 Hz |
60 Hz |
Travel speed m/min |
7.5 / 30 |
9 / 36 |
Duty cycle FEM |
50 % | |
Switching rate FEM c/h |
240 (at
3 m) | |
Rated power kW |
0.14 / 0.65 |
0.17 / 0.78 |
Motor speed rpm |
620 / 2750 |
775 / 3350 |
Start-up current A |
1.45 / 8.10 | |
Rated current A |
0.68 / 1.68 | |
cos phi A |
0.80 / 0.82 |
0.75 / 0.77 |
cos phi N |
0.67 / 0.86 |
0.66 / 0.87 |
Part number |
90158 | |
Operating voltage |
380 – 415 V |
440 – 480 V |
Frequency |
50 Hz |
60 Hz |
Travel speed m/min |
10 / 40 |
12 / 48 |
Duty cycle FEM |
50 % | |
Switching rate FEM c/h |
240 (at
3 m) | |
Rated power kW |
0.18 / 0.80 |
0.22 / 0.96 |
Motor speed rpm |
620 / 2780 |
760 / 3330 |
Start-up current A |
1.75 / 10.1 | |
Rated current A |
0.92 / 2.10 | |
cos phi A |
0.75 / 0.85 |
0.69 / 0.81 |
cos phi N |
0.65 / 0.84 |
0.64 / 0.85 |
Part number |
3117 | |
Operating voltage |
380 – 415 V |
440 – 480 V |
Frequency |
50 Hz |
60 Hz |
Travel speed m/min |
10 / 40 |
12 / 48 |
Duty cycle FEM |
50 % | |
Switching rate FEM c/h |
240 (at
3 m) | |
Rated power kW |
0.14 / 0.65 |
0.17 / 0.78 |
Motor speed rpm |
620 / 2750 |
775 / 3350 |
Start-up current A |
1.45 / 8.10 | |
Rated current A |
0.68 / 1.68 | |
cos phi A |
0.80 / 0.82 |
0.75 / 0.77 |
cos phi N |
0.67 / 0.86 |
0.66 / 0.87 |
Part number |
12987 | |
Operating voltage |
380 – 415 V |
440 – 480 V |
Frequency |
50 Hz |
60 Hz |
Travel speed m/min |
12.5 / 50 |
15 / 60 |
Duty cycle FEM |
40 % | |
Switching rate FEM c/h |
240 (at
3 m) | |
Rated power kW |
0.18 / 0.80 |
0.22 / 0.96 |
Motor speed rpm |
620 / 2780 |
760 / 3330 |
Start-up current A |
1.75 / 10.1 | |
Rated current A |
0.92 / 2.10 | |
cos phi A |
0.75 / 0.85 |
0.69 / 0.81 |
cos phi N |
0.65 / 0.84 |
0.64 / 0.85 |
Part number |
3122 | |
Operating voltage |
380 – 415 V |
440 – 480 V |
Frequency |
50 Hz |
60 Hz |
Travel speed m/min |
12.5 / 50 |
15 / 60 |
Duty cycle FEM |
40 % | |
Switching rate FEM c/h |
240 (at
3 m) | |
Rated power kW |
0.14 / 0.65 |
0.17 / 0.78 |
Motor speed rpm |
620 / 2750 |
775 / 3350 |
Start-up current A |
1.45 / 8.10 | |
Rated current A |
0.68 / 1.68 | |
cos phi A |
0.80 / 0.82 |
0.75 / 0.77 |
cos phi N |
0.67 / 0.86 |
0.66 / 0.87 |
Part number |
12988 | |
Operating voltage |
380 – 415 V |
440 – 480 V |
Frequency |
50 Hz |
60 Hz |
Travel speed m/min |
15 / 60 |
18 / 72 |
Duty cycle FEM |
40 % | |
Switching rate FEM c/h |
150 (at
1 Am) | |
Rated power kW |
0.18 / 0.80 |
0.22 / 0.96 |
Motor speed rpm |
620 / 2780 |
760 / 3330 |
Start-up current A |
1.75 / 10.1 | |
Rated current A |
0.92 / 2.10 | |
cos phi A |
0.75 / 0.85 |
0.69 / 0.81 |
cos phi N |
0.65 / 0.84 |
0.64 / 0.85 |
Part number |
3123 | |
Operating voltage |
380 – 415 V |
440 – 480 V |
Frequency |
50 Hz |
60 Hz |
Travel speed m/min |
15 / 60 |
18 / 72 |
Duty cycle FEM |
40 % | |
Switching rate FEM c/h |
150 (at
1 Am) | |
Rated power kW |
0.14 / 0.65 |
0.17 / 0.78 |
Motor speed rpm |
620 / 2750 |
775 / 3350 |
Start-up current A |
1.45 / 8.10 | |
Rated current A |
0.68 / 1.68 | |
cos phi A |
0.80 / 0.82 |
0.75 / 0.77 |
cos phi N |
0.67 / 0.86 |
0.66 / 0.87 |
Part number |
12997 | |
Operating voltage |
380 – 415 V |
440 – 480 V |
Frequency |
50 Hz |
60 Hz |
Travel speed m/min |
15 / 60 |
18 / 72 |
Duty cycle FEM |
40 % | |
Switching rate FEM c/h |
150 (at
1 Am) | |
Rated power kW |
0.18 / 0.80 |
0.22 / 0.96 |
Motor speed rpm |
620 / 2780 |
760 / 3330 |
Start-up current A |
1.75 / 10.1 | |
Rated current A |
0.92 / 2.10 | |
cos phi A |
0.75 / 0.85 |
0.69 / 0.81 |
cos phi N |
0.65 / 0.84 |
0.64 / 0.85 |
Electrical data AZP 280:
Part number |
87054 | |
Operating voltage |
380 – 415 V |
440 – 480 V |
Frequency |
50 Hz |
60 Hz |
Travel speed m/min |
5 / 20 |
6 / 24 |
Duty cycle FEM |
50 % | |
Switching rate FEM c/h |
240 (at
3 m) | |
Rated power kW |
0.14 / 0.65 |
0.17 / 0.78 |
Motor speed rpm |
620 / 2750 |
775 / 3350 |
Start-up current A |
1.45 / 8.10 | |
Rated current A |
0.68 / 1.68 | |
cos phi A |
0.80 / 0.82 |
0.75 / 0.77 |
cos phi N |
0.67 / 0.86 |
0.66 / 0.87 |
Part number |
87056 | |
Operating voltage |
380 – 415 V |
440 – 480 V |
Frequency |
50 Hz |
60 Hz |
Travel speed m/min |
5 / 20 |
6 / 24 |
Duty cycle FEM |
50 % | |
Switching rate FEM c/h |
240 (at
3 m) | |
Rated power kW |
0.18 / 0.80 |
0.22 / 0.96 |
Motor speed rpm |
620 / 2780 |
760 / 3330 |
Start-up current A |
1.75 / 10.1 | |
Rated current A |
0.92 / 2.10 | |
cos phi A |
0.75 / 0.85 |
0.69 / 0.81 |
cos phi N |
0.65 / 0.84 |
0.64 / 0.85 |
Part number |
87057 | |
Operating voltage |
380 – 415 V |
440 – 480 V |
Frequency |
50 Hz |
60 Hz |
Travel speed m/min |
7.5 / 30 |
9 / 36 |
Duty cycle FEM |
50 % | |
Switching rate FEM c/h |
240 (at 3 m) 300 (at 4 m) | |
Rated power kW |
0.18 / 0.80 |
0.22 / 0.96 |
Motor speed rpm |
620 / 2780 |
760 / 3330 |
Start-up current A |
1.75 / 10.1 | |
Rated current A |
0.92 / 2.10 | |
cos phi A |
0.75 / 0.85 |
0.69 / 0.81 |
cos phi N |
0.65 / 0.84 |
0.64 / 0.85 |
Part number |
87055 | |
Operating voltage |
380 – 415 V |
440 – 480 V |
Frequency |
50 Hz |
60 Hz |
Travel speed m/min |
10 / 40 |
12 / 48 |
Duty cycle FEM |
50 % | |
Switching rate FEM c/h |
240 (at 3 m) 300 (at 4 m) | |
Rated power kW |
0.14 / 0.65 |
0.17 / 0.78 |
Motor speed rpm |
620 / 2750 |
775 / 3350 |
Start-up current A |
1.45 / 8.10 | |
Rated current A |
0.68 / 1.68 | |
cos phi A |
0.80 / 0.82 |
0.75 / 0.77 |
cos phi N |
0.67 / 0.86 |
0.66 / 0.87 |
Part number |
87058 | |
Operating voltage |
380 – 415 V |
440 – 480 V |
Frequency |
50 Hz |
60 Hz |
Travel speed m/min |
10 / 40 |
12 / 48 |
Duty cycle FEM |
50 % | |
Switching rate FEM c/h |
240 (at 3 m) 300 (at 4 m) | |
Rated power kW |
0.18 / 0.80 |
0.22 / 0.96 |
Motor speed rpm |
620 / 2780 |
760 / 3330 |
Start-up current A |
1.75 / 10.1 | |
Rated current A |
0.92 / 2.10 | |
cos phi A |
0.75 / 0.85 |
0.69 / 0.81 |
cos phi N |
0.65 / 0.84 |
0.64 / 0.85 |
Part number |
87061 | |
Operating voltage |
380 – 415 V |
440 – 480 V |
Frequency |
50 Hz |
60 Hz |
Travel speed m/min |
10 / 40 |
12 / 48 |
Duty cycle FEM |
50 % | |
Switching rate FEM c/h |
240 (at 3 m) 300 (at 4 m) | |
Rated power kW |
0.25 / 1.10 |
0.30 / 1.32 |
Motor speed rpm |
640 / 2790 |
785 / 3380 |
Start-up current A |
2.75 / 16.1 | |
Rated current A |
1.13 / 2.26 | |
cos phi A |
0.74 / 0.82 |
0.66 / 0.78 |
cos phi N |
0.58 / 0.89 |
0.57 / 0.91 |
Part number |
87059 | |
Operating voltage |
380 – 415 V |
440 – 480 V |
Frequency |
50 Hz |
60 Hz |
Travel speed m/min |
12.5 / 50 |
15 / 60 |
Duty cycle FEM |
40 % | |
Switching rate FEM c/h |
240 (at
3 m) | |
Rated power kW |
0.18 / 0.80 |
0.22 / 0.96 |
Motor speed rpm |
620 / 2780 |
760 / 3330 |
Start-up current A |
1.75 / 10.1 | |
Rated current A |
0.92 / 2.10 | |
cos phi A |
0.75 / 0.85 |
0.69 / 0.81 |
cos phi N |
0.65 / 0.84 |
0.64 / 0.85 |
Part number |
87062 | |
Operating voltage |
380 – 415 V |
440 – 480 V |
Frequency |
50 Hz |
60 Hz |
Travel speed m/min |
12.5 / 50 |
15 / 60 |
Duty cycle FEM |
40 % | |
Switching rate FEM c/h |
240 (at
3 m) | |
Rated power kW |
0.25 / 1.10 |
0.30 / 1.32 |
Motor speed rpm |
640 / 2790 |
785 / 3380 |
Start-up current A |
2.75 / 16.1 | |
Rated current A |
1.13 / 2.26 | |
cos ϕA |
0.74 / 0.82 |
0.66 / 0.78 |
cos ϕN |
0.58 / 0.89 |
0.57 / 0.91 |
Part number |
87060 | |
Operating voltage |
380 – 415 V |
440 – 480 V |
Frequency |
50 Hz |
60 Hz |
Travel speed m/min |
15 / 60 |
18 / 72 |
Duty cycle FEM |
40 % | |
Switching rate FEM c/h |
150 (at 1 Am) 180 (at 2m) | |
Rated power kW |
0.18 / 0.80 |
0.22 / 0.96 |
Motor speed rpm |
620 / 2780 |
760 / 3330 |
Start-up current A |
1.75 / 10.1 | |
Rated current A |
0.92 / 2.10 | |
cos phi A |
0.75 / 0.85 |
0.69 / 0.81 |
cos phi N |
0.65 / 0.84 |
0.64 / 0.85 |
Part number |
87063 | |
Operating voltage |
380 – 415 V |
440 – 480 V |
Frequency |
50 Hz |
60 Hz |
Travel speed m/min |
15 / 60 |
18 / 72 |
Duty cycle FEM |
40 % | |
Switching rate FEM c/h |
150 (at 1 Am) 180 (at 2m) | |
Rated power kW |
0.25 / 1.10 |
0.30 / 1.32 |
Motor speed rpm |
640 / 2790 |
785 / 3380 |
Start-up current A |
2.75 / 16.1 | |
Rated current A |
1.13 / 2.26 | |
cos phi A |
0.74 / 0.82 |
0.66 / 0.78 |
cos phi N |
0.58 / 0.89 |
0.57 / 0.91 |