Setting the waiting time

How long the transmitter should wait after login and release before the crane can be controlled is set here.

The waiting time makes sense particularly with cranes with ABULiner frequency converter or with ABUControl.

The waiting time is shown in the form of a progress bar on the display and conveys to the crane operator that the control is currently being started up.

With ABUControl, the waiting time is fixedly specified via the PLC of the control.

 

 

Opening the menu item “Waiting time”

The menu item can only be opened with the transmitter logged in.

 

Menu item “Waiting time”

 

*   Hold MENU depressed (5 seconds).

●   The code query appears on the display.

*   Enter the code for the service menu.

See Entering the code or PIN.

The code for the service menu is “0055”.

*   Open the menu item “Waiting time”.

 

 

Setting and displaying the waiting time

Set waiting time

 

●   The waiting time currently set is shown on the display.

*   Set the required value.

The waiting time can be set in 5-second steps between 5 and 30 seconds, or switched off.

The value “Off” is sorted in the list in front of the value “5 s” and can be reached by scrolling multiple times.

*   Confirm using ENTER.