Frequency converter:
|
Electrical connection | |
|
Operating voltage |
3 x 380 – 480 V ± 10 % |
|
Mains frequency |
50/60 Hz ± 5 Hz |
|
Max. imbalance operating voltage |
± 3.0% of operating voltage |
|
Effective power factor (λ) |
0.9 |
|
cos φ |
> 0.98 |
|
Switches on connection cable |
2x / min |
|
Max. short-circuit current |
100000 A |
|
Control voltage |
24 V DC |
|
Cable lengths | |
|
Maximum length of connection cable to hoist motor for shielded wiring |
40 m |
|
Maximum length of connection cable to hoist motor for non-shielded wiring |
75 m |
|
Maximum length of connection cable to hoist motor for shielded wiring and smoothing choke |
100 m |
For longer connection cables to the hoist motor (for example, for central contactor boxes), an output filter is connected between the frequency converter and the hoist motor.
|
Ambient conditions for operation | |
|
Protection class |
IP 20 |
|
Relative humidity |
5 % to 95 % |
|
Ambient temperature |
0 °C to +45 °C |
|
Maximum average temperature within 24 hours |
40 °C |
|
Maximum elevation above sea level |
3000 m |
If the temperature of the hoist panel regularly exceeds 60°C due to extreme ambient conditions, the hoist panel must also be cooled. Depending on the size of the hoist panel, a panel lid with fans or one or two heat exchangers can be installed.
Frequency converter:
|
Electrical connection | |
|
Operating voltage |
3 x 380 – 480 V ± 10 % |
|
Network demand, network short circuit |
≤ 1 % |
|
Mains frequency |
47 - 63 Hz |
|
Effective power factor (λ) |
0.9 |
|
Efficiency |
95 - 97 % |
|
Control factor |
87 % |
|
Control voltage |
24 V DC |
|
Cable lengths | |
|
Maximum length of connection cable to hoist motor for shielded wiring |
25 m |
|
Maximum length of connection cable to hoist motor for non-shielded wiring |
100 m |
For longer connection cables to the hoist motor (for example, for central contactor boxes), an output filter is connected between the frequency converter and the hoist motor.
|
Ambient conditions for operation | |
|
Protection class |
IP 20 |
|
Relative humidity |
< 95 % |
|
Ambient temperature |
-10 - +50° C |
|
Maximum elevation above sea level |
Up to 1000 m above sea level without power reduction |
If the temperature of the hoist panel regularly exceeds 60°C due to extreme ambient conditions, the hoist panel must also be cooled. Depending on the size of the hoist panel, a panel lid with fans or one or two heat exchangers can be installed.
Frequency converter:
|
Electrical connection | |
|
Operating voltage |
380 ‒ 480 V -15 - +10 % |
|
Mains frequency |
50 ‒ 60 Hz +/- 5 % |
|
Control voltage |
24 V DC |
|
Cable lengths | |
|
Maximum length of connection cable without smoothing choke |
50 m |
|
Maximum length of connection cable to hoist motor for shielded wiring |
100 m |
|
Maximum length of connection cable to hoist motor for non-shielded wiring |
200 m |
For longer connection cables to the hoist motor (for example, for central contactor boxes), an output filter is connected between the frequency converter and the hoist motor.
|
Ambient conditions for operation | |
|
Protection class |
IP 20 |
|
Relative humidity |
5 % ‒ 95 % |
|
Ambient temperature without power reduction |
-15 ‒ 50° C |
|
Ambient temperature with power reduction |
50 – 60° C |
|
Maximum elevation above sea level without power reduction |
Up to 1000 m above sea level |
|
Maximum elevation above sea level with power reduction |
Up to 4800 m above sea level |
If the temperature of the hoist panel regularly exceeds 60°C due to extreme ambient conditions, the hoist panel must also be cooled. Depending on the size of the hoist panel, a panel lid with fans or one or two heat exchangers can be installed.
|
Voltages on pin plugs |
|
|
Pin plug X3 |
400 V AC, 2 A |
|
Pins |
48 V, 110 V or 230 V (see type plate) electrically isolated |
|
Ambient conditions for operation | |
|
Housing |
IP 20 |
|
Relative humidity |
5 % to 85 % |
|
Ambient temperature |
-10 °C to 40 °C |
|
Electrical connection |
|
|
Operating voltage |
24 V |
|
Current consumption |
Max. 50 mA |
|
Outputs |
|
|
Rotational direction output |
Clockwise = Anti-clockwise = |
|
Speed 1 output |
2000 impulses/rotation |
|
Speed 2 output |
1000 impulses/rotation |
|
Speed 3 output |
100 impulses/rotation |
|
Ambient conditions for operation | |
|
Housing |
Installation in a housing with IP 54 required |
|
Relative humidity |
5 % ‒ 85 % |
|
Ambient temperature |
-10° C ‒ 55° C |
LIS-SV: