Frequency converter:
Electrical connection | |
Operating voltage |
3 x 380 – 480 V ± 10 % |
Mains frequency |
50/60 Hz ± 5 Hz |
Max. imbalance operating voltage |
± 3.0% of operating voltage |
Effective power factor (λ) |
0.9 |
cos φ |
> 0.98 |
Switches on connection cable |
2x / min |
Max. short-circuit current |
100000 A |
Control voltage |
24 V DC |
Cable lengths | |
Maximum length of connection cable to hoist motor for shielded wiring |
40 m |
Maximum length of connection cable to hoist motor for non-shielded wiring |
75 m |
Maximum length of connection cable to hoist motor for shielded wiring and smoothing choke |
100 m |
For longer connection cables to the hoist motor (for example, for central contactor boxes), an output filter is connected between the frequency converter and the hoist motor.
Ambient conditions for operation | |
Protection class |
IP 20 |
Relative humidity |
5 % to 95 % |
Ambient temperature |
0 °C to +45 °C |
Maximum average temperature within 24 hours |
40 °C |
Maximum elevation above sea level |
3000 m |
If the temperature of the hoist panel regularly exceeds 60°C due to extreme ambient conditions, the hoist panel must also be cooled. Depending on the size of the hoist panel, a panel lid with fans or one or two heat exchangers can be installed.
Frequency converter:
Electrical connection | |
Operating voltage |
3 x 380 – 480 V ± 10 % |
Network demand, network short circuit |
≤ 1 % |
Mains frequency |
47 - 63 Hz |
Effective power factor (λ) |
0.9 |
Efficiency |
95 - 97 % |
Control factor |
87 % |
Control voltage |
24 V DC |
Cable lengths | |
Maximum length of connection cable to hoist motor for shielded wiring |
25 m |
Maximum length of connection cable to hoist motor for non-shielded wiring |
100 m |
For longer connection cables to the hoist motor (for example, for central contactor boxes), an output filter is connected between the frequency converter and the hoist motor.
Ambient conditions for operation | |
Protection class |
IP 20 |
Relative humidity |
< 95 % |
Ambient temperature |
-10 - +50° C |
Maximum elevation above sea level |
Up to 1000 m above sea level without power reduction |
If the temperature of the hoist panel regularly exceeds 60°C due to extreme ambient conditions, the hoist panel must also be cooled. Depending on the size of the hoist panel, a panel lid with fans or one or two heat exchangers can be installed.
Frequency converter:
Electrical connection | |
Operating voltage |
380 ‒ 480 V -15 - +10 % |
Mains frequency |
50 ‒ 60 Hz +/- 5 % |
Control voltage |
24 V DC |
Cable lengths | |
Maximum length of connection cable without smoothing choke |
50 m |
Maximum length of connection cable to hoist motor for shielded wiring |
100 m |
Maximum length of connection cable to hoist motor for non-shielded wiring |
200 m |
For longer connection cables to the hoist motor (for example, for central contactor boxes), an output filter is connected between the frequency converter and the hoist motor.
Ambient conditions for operation | |
Protection class |
IP 20 |
Relative humidity |
5 % ‒ 95 % |
Ambient temperature without power reduction |
-15 ‒ 50° C |
Ambient temperature with power reduction |
50 – 60° C |
Maximum elevation above sea level without power reduction |
Up to 1000 m above sea level |
Maximum elevation above sea level with power reduction |
Up to 4800 m above sea level |
If the temperature of the hoist panel regularly exceeds 60°C due to extreme ambient conditions, the hoist panel must also be cooled. Depending on the size of the hoist panel, a panel lid with fans or one or two heat exchangers can be installed.
Voltages on pin plugs |
|
Pin plug X3 |
400 V AC, 2 A |
Pins |
48 V, 110 V or 230 V (see type plate) electrically isolated |
Ambient conditions for operation | |
Housing |
IP 20 |
Relative humidity |
5 % to 85 % |
Ambient temperature |
-10 °C to 40 °C |
Electrical connection |
|
Operating voltage |
24 V |
Current consumption |
Max. 50 mA |
Outputs |
|
Rotational direction output |
Clockwise = Anti-clockwise = |
Speed 1 output |
2000 impulses/rotation |
Speed 2 output |
1000 impulses/rotation |
Speed 3 output |
100 impulses/rotation |
Ambient conditions for operation | |
Housing |
Installation in a housing with IP 54 required |
Relative humidity |
5 % ‒ 85 % |
Ambient temperature |
-10° C ‒ 55° C |
LIS-SV:
See “LIS-SV operating manual”