Technical data

Only with Danfoss frequency converter

 

Frequency converter:

Electrical connection

Operating voltage

3 x 380 – 480 V ± 10 %

Mains frequency

50/60 Hz ± 5 Hz

Max. imbalance operating voltage

± 3.0% of operating voltage

Effective power factor (λ)

0.9

cos φ

> 0.98

Switches on connection cable

2x / min

Max. short-circuit current

100000 A

Control voltage

24 V DC

 

Cable lengths

Maximum length of connection cable to hoist motor for shielded wiring

40 m

Maximum length of connection cable to hoist motor for non-shielded wiring

75 m

Maximum length of connection cable to hoist motor for shielded wiring and smoothing choke

100 m

For longer connection cables to the hoist motor (for example, for central contactor boxes), an output filter is connected between the frequency converter and the hoist motor.

 

Ambient conditions for operation

Protection class

IP 20

Relative humidity

5 % to 95 %
(non-condensing)

Ambient temperature

0 °C to +45 °C

Maximum average temperature within 24 hours

40 °C

Maximum elevation above sea level

3000 m

If the temperature of the hoist panel regularly exceeds 60°C due to extreme ambient conditions, the hoist panel must also be cooled. Depending on the size of the hoist panel, a panel lid with fans or one or two heat exchangers can be installed.

 

 

 

Only with Siemens frequency converter

 

Frequency converter:

Electrical connection

Operating voltage

3 x 380 – 480 V ± 10 %

Network demand, network short circuit

≤ 1 %

Mains frequency

47 - 63 Hz

Effective power factor (λ)

0.9

Efficiency

95 - 97 %

Control factor

87 %

Control voltage

24 V DC

 

Cable lengths

Maximum length of connection cable to hoist motor for shielded wiring

25 m

Maximum length of connection cable to hoist motor for non-shielded wiring

100 m

For longer connection cables to the hoist motor (for example, for central contactor boxes), an output filter is connected between the frequency converter and the hoist motor.

 

Ambient conditions for operation

Protection class

IP 20

Relative humidity

< 95 %
(non-condensing)

Ambient temperature

-10 - +50° C

Maximum elevation above sea level

Up to 1000 m above sea level without power reduction

If the temperature of the hoist panel regularly exceeds 60°C due to extreme ambient conditions, the hoist panel must also be cooled. Depending on the size of the hoist panel, a panel lid with fans or one or two heat exchangers can be installed.

 

 

 

Only with the Schneider frequency converter

 

Frequency converter:

Electrical connection

Operating voltage

380 ‒ 480 V -15 - +10 %

Mains frequency

50 ‒ 60 Hz +/- 5 %

Control voltage

24 V DC

 

Cable lengths

Maximum length of connection cable without smoothing choke

50 m

Maximum length of connection cable to hoist motor for shielded wiring

100 m

Maximum length of connection cable to hoist motor for non-shielded wiring

200 m

For longer connection cables to the hoist motor (for example, for central contactor boxes), an output filter is connected between the frequency converter and the hoist motor.

 

Ambient conditions for operation

Protection class

IP 20

Relative humidity

5 % ‒ 95 %
(non-condensing)

Ambient temperature without power reduction

-15 ‒ 50° C

Ambient temperature with power reduction

50 – 60° C

Maximum elevation above sea level without power reduction

Up to 1000 m above sea level

Maximum elevation above sea level with power reduction

Up to 4800 m above sea level

If the temperature of the hoist panel regularly exceeds 60°C due to extreme ambient conditions, the hoist panel must also be cooled. Depending on the size of the hoist panel, a panel lid with fans or one or two heat exchangers can be installed.

 

 

 

Control unit:

Voltages on pin plugs

 

Pin plug X3
brake

400 V AC, 2 A

Pins
X1 1 to X1 5

48 V, 110 V or 230 V

(see type plate)

electrically isolated

 

Ambient conditions for operation

Housing

IP 20

Relative humidity

5 % to 85 %

Ambient temperature

-10 °C to 40 °C

 

 

Encoder:

Electrical connection

 

Operating voltage

24 V

Current consumption

Max. 50 mA

 

Outputs

 

Rotational direction output
(yellow)

Clockwise =
positive signal

Anti-clockwise =
negative signal

Speed 1 output
(grey)

2000 impulses/rotation

Speed 2 output
(green)

1000 impulses/rotation
(not used for ABULiner)

Speed 3 output
(brown)

100 impulses/rotation
(not used for ABULiner)

 

Ambient conditions for operation

Housing

Installation in a housing with IP 54 required

Relative humidity

5 % ‒ 85 %

Ambient temperature

-10° C ‒ 55° C

 

LIS-SV:

See “LIS-SV operating manual”