Electrical connection: | |||
Nominal voltage |
380 V |
400 V |
415 V |
Operating voltage |
370 – 400 V |
375 – 420 V |
380 – 435 V |
Mains frequency |
50 Hz |
50 Hz |
50 Hz |
Control voltage |
24 V DC |
24 V DC |
24 V DC |
Electrical connection: | |||
Nominal voltage |
440 V |
460 V |
480 V |
Operating voltage |
425 – 460 V |
430 – 485 V |
445 – 505 V |
Mains frequency |
60 Hz |
60 Hz |
60 Hz |
Control voltage |
24 V DC |
24 V DC |
24 V DC |
Ambient conditions for operation: | |
Ambient temperature |
-5°C to 40°C |
Ambient temperature (for reduced duty cycle) |
+40°C to +65°C |
Installation altitude |
Up to 1000 m above sea level |
ABUControl can also be used at a reduced duty cycle and switching rate from +40 °C to +65 °C.
Operation at higher ambient temperatures:
Duty cycle of drives according to type plate |
Modified duty cycle at
ambient temperatures of |
60 % |
30 % |
50 % |
25 % |
40 % |
20 % |
For ambient temperatures of +40 °C to +65 °C, reduce the duty cycle according to the tables.
Operation at higher elevations:
At higher elevations, the crane will be less well cooled due to the reduced air pressure.
Reduce the duty cycle at higher elevations.