Setting basic parameters for movement profiles (travel profiles and hoist profile) [1]

The movement profiles of all three crane axes (crane travel profile, trolley travel profile, hoist profile) can be adjusted to individual usage in the acceleration and braking behaviour.

For this work step, access from a laptop or tablet computer to KranOS is necessary. The user "Service" (user level [1]) must be logged in.

 

 

Opening parameters for movement profile

Overview: Navigation in KranOS

User "Service" à "Movement profile parameter"

Note:

The "Movement profile parameter" window is the only window in KranOS that can be opened by the "Service" user but not by the "Abnahme" (commissioning) user. For all other windows that can be opened by the "Service" user, they can also be opened by the "Abnahme" (commissioning) user, since the "Abnahme" (commissioning) user has higher-level authorisations than the "Service" user.

The parameters in the "Movement profile parameter" window are however only summarised here for the "Service" user.

The parameters can be set by the "Abnahme" (commissioning) user in addition to many other parameters in the windows "Crane travel profile parameter" (or "Trolley travel profile parameter" or "Hoist profile parameter").

 

* Log in to KranOS with user "Service" (user level [1]). See Connecting laptop or tablet computer with ABUControl, page  .

* In the start window: Click on the "Movement profile parameter" menu item in the "Settings" menu (gear wheel on yellow background).

 

Setting parameters

Braking time

Acceleration time

●   The "Movement profile parameter" window appears.

●   The current settings are displayed.

─    Set the desired values:

Warnung Vorsicht

Danger due to too short braking time and acceleration time

If the braking time or acceleration time is set too short, excessive load can be placed on the statics of the supporting structure (e.g. of the building) and damage it.

Before changing the parameter, contact ABUS Service.

 

Warnung Vorsicht

Danger due to too long braking time

If the braking time is too long, the crane (the trolley) could possibly not come to a stop in time to avoid colliding with other cranes (trolleys).

After changing the parameter, test the braking time.

─     "Braking time": Time in which the drive brakes from the travel speed according to the type plate until reaching a stop. The crane (or trolley) brakes faster at a low value and slower at a high value. The shortest and longest time that can be set is displayed during input in the key field.

─     "Acceleration time": Time in which the drive accelerates to the travel speed according to the type plate. The crane (or trolley) accelerates faster at a low value and slower at a high value. The shortest and longest time that can be set is displayed during input in the key field.

* Click on the "Write PLC" button.