During assembly, the connection cables are placed through the cable entry housing into the panel and connected. All connection cables can be plugged in. The cable ducts in the cable entry housing are used as strain relief and seals.
Cable entry housing |
|
| |
Cover |
|
Lightly push the two clip fasteners at the
top outwards.
At the same time, pull the upper part of the
cover away from the housing.
Tilt the cover downwards until it is almost
horizontal.
● The cover will be automatically released from the lower clip fasteners when it is tilted.
Tip:
If the cover cannot be tipped downwards due to space limitations, its upper and lower clip fasteners can also be pressed outwards and the cover can then be simply taken off.
Connection cable |
|
| |
Cable bushing |
Cable locking latch |
Push the connection cable through the cable
bushing until the connection cable can be guided up to the terminal block in the
panel.
Connect the cable locking latch to the
connection cable from outside.
Connection cable with cable locking latch |
Cable strain relief base unit |
| |
Cable strain relief clamping bracket |
|
Put the cable strain relief base unit into
the cable entry housing and latch it in.
Push the connection cable with the cable
locking latch into the base unit and simultaneously guide the cable bushing
(rubber) into the opening in the cable entry housing.
Connect the cable strain relief clamping
bracket to the base unit.
Opening for cable ties |
|
| |
Opening for cable ties |
|
Push the cable ties (not in the figure) into
the opening on the cable strain relief.
● The cable tie is guided along the cable strain relief basic unit and comes out again at the other opening.
Put the cable ties together and hand-tighten
them.
Cable strain relief base unit |
Cable duct |
| |
Cable entry housing |
Cable ties |
Push the cable duct into the rail on the
cable entry housing (below in the figure)
or
Push the cable duct into the rail between two cable strain relief base units (above in the figure).
Attach the connection cable onto the cable
duct with cable ties.
Clip fastener |
|
| |
|
Cover |
Place all four corners of the cover onto the
housing.
Clip the cover into all four clip fasteners
at the same time.