For cranes with short end carriages, the wiring and the cable entry housing are on the crane control in front of the high-tensile bolt. The cable entry housing must be removed in order to be able to tighten or loosen high-tensile bolts.
Cable entry housing |
|
Catch |
|
Open the crane control cover.
Press in the front four catches from the cable entry housing.
Tip the cable entry housing backwards (in the direction of the rear of the panel).
● The cable entry housing is removed from the panel.
Pull the cable entry housing forwards.
● The cable entry housing can hang loosely with the wiring on the crane control until the high-tensile bolts are tightened.
Cable entry housing |
|
Set the cable entry housing straight on the panel.
Press the cable entry housing into the panel.
● Latch in the catches (8x) with a clicking sound.